8.2.1 Standard/CiA 402
Image 8.3: “Standardization profile - Standard/CiA 402 - Units” screen
NOTE
l
The scaling is entered using exponent syntax.
NOTE
l
When using interpolating operation modes (CSV, CSP, CST) via
fieldbus, scaling must be performed using the CiA402 scaling
assistant.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
227
8 Motion profile
Image 8.4: “Standardization profile - Standard/CiA 402 - Direction of rotation” screen
Referred to the motor, the positive direction is clockwise as seen when looking at the
motor shaft (A-side bearing plate).