11.6.45 Error 49: Safety system error
11.6.45.1 Error 49-0 (emergency code 6100h)
Cause: Unknown fatal error in functional safety interface
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo controller.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
442
11 Alarms & warnings
11.6.45.2 Error 49-1 (emergency code 6100h)
Cause: Alarm on safety controller SR1 of master or local device detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extended diagnosis of safety
errors/alarms.
l
Further information on the error/alarm code
can be found in the "ServoOne functional
Safety Error Description".
An alarm occured at the
safety controller.
l
Please check the safety program and the
wiring of the safety system.
l
Please acknowledge the alarm at the safety
master. The safety master acknowledges all
slave alarms and resets the network status to
"RUN".