ID
Index Name
Unit Description
429
0
ISA00_gain
Gain scaling for input ISA00
429
1
ISA01_gain
Gain scaling for input ISA01
429
2
ISA00_limMin
Minimum value for input ISA00
429
3
ISA01_limMin
Minimum value for input ISA01
429
4
ISA00_limMax
Maximum value for input ISA00
429
5
ISA01_limMax
Maximum value for input ISA01
665
0
DV_CAL_IsaType
Analogue inputs: Switch between current/voltage
input
Table 9.11: “Analogue inputs” parameters (continue)
9.4.2 Function selectors
Before using the analogue inputs, they are normally associated with a special
device functionality for analogue inputs. The corresponding function selectors also
make it possible to select a special digital functionality instead.
ID
Index Name / Setting
Unit Description
109-110
0
MPRO_INPUT_FS_
ISA0x
“Analogue inputs” “function selectors”
PRC_REF (-14)
Process controller reference value
PRC_ACT (-13)
Process controller actual value
ENC_ANA (-12)
Analogue encoder (on channel 4)
TWIN_SCALE (-11)
TWIN position scaling
HYD_Q_ACT (-10)
Hydraulic actual flow (software specific)
HYD_P_ACT2 (-9)
Hydraulic actual pressure on 2nd sensor
(software specific)
HYD_Q_REF (-8)
Hydraulic reference flow (software specific)
HYD_P_ACT (-7)
Hydraulic actual pressure (software specific)
HYD_P_REF (-6)
Hydraulic reference pressure (software specific)
VFC_REF_SCALE (-5)
VFC reference scaling 0-100% (software
specific)
TLIM (-4)
Analogue torque limit 0-100%
OVR (-3)
Speed override 0-100% at positioning
Table 9.12: “Analogue inputs” function selectors
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
317
9 Inputs/Outputs settings
ID
Index Name / Setting
Unit Description
REFV (-2)
Analogue reference
(-1)
Not defined
Off (0)
No function
START (1)
Start motor control
INV (2)
Inverse reference value
STOP (3)
Execute quickstop
HALT (4)
Disable feed
LCW (5)
Limit switch positive direction
LCCW (6)
Limit switch negative direction
INCH_P (7)
Jog Positive
INCH_N (8)
Jog Negative
HOMST (9)
Start homing
HOMSW (10)
Reference switch
E_EXT (11)
External error
WARN (12)
External warning
RSERR (13)
Reset alarm
MAN (14)
Switch control location selector
(15)
Not defined
PLC (16)
Used in PLC
PLC_IR (17)
PLC interrupt
MP_UP (18)
Motor potentiometer Negative
MP_DOWN (19)
Motor potentiometer Positive
(20) - (20)
Not defined
TBEN (21)
Enable selected table index
TBTEA (22)
Write actual position into selected table index
TAB0 (23)
Binary table index 2^0
TAB1 (24)
Binary table index 2^1
TAB2 (25)
Binary table index 2^2
TAB3 (26)
Binary table index 2^3
EGEAR (27)
Start / stop Egear
REFANAEN (28)
Enable analogue reference
(29)
Not defined
(30)
Not defined