ID
Index Name
Unit
Description
2677
0
CON_PRC_ACTVAL_
FIELDBUS
Current fieldbus value
2678
0
CON_PRC_OUTSEL_
MOPRO
Process controller: output value for motion
profile
2679
0
CON_PRC_RefReached USER “Reference value reached” window
2680
CON_PRC_RateLimiter
Process controller: rate limiting
2680
0
CON_PRC_RateLimiter
x/ms
Slope limitation (Process)
2680
1
CON_PRC_RateLimiter
x/ms
Process controller: rate limiting, reset I-
component
2681
0
CON_PRC_CtrlWord
Process controller: control word
2682
0
CON_PRC_StatWord
Process controller: status word
2683
0
CON_PRC_REFSEL
Process controller: selection of the reference
value
2684
0
CON_PRC_REFVAL_
User
Process controller: reference value from user
Table 7.48: “Process controller” parameters (continue)
7.10.5 Scope signals
ID
Index Parameter name
Unit Function
2675
0
CON_PRC_Cdiff_
Technological controller: control deviation
Process control: control deviation
2666
0
CON_PRC_RefVal
Technological controller: setpoint
Process control reference value
2673
0
CON_PRC_Raw_ActVal
Istwert des Eingangssignals
Actual value of input signal
2674
0
CON_PRC_ACTVAL
Eingangssignal nach Skalierung und Filterung
Input signal after scaling and filtering
2676
0
CCON_PRC_Outval
Technological controller: output value
Process control output value
Table 7.49: Parameters relevant for visualizing the process control circuit in the
scope
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
175
7 Control
7.11 Hydraulic control
Firmware with a version range of V270.xx-xx includes special hydraulic parameters
in addition to the standard firmware. These can be used to control pressure,
volumetric flow rate, cylinder speed, and cylinder position, making it easy to
implement hydraulic system applications. The firmware is available for ServoOne,
ServoOne junior and ServoOne safety.
The descriptions in this chapter apply to version V274.30-xx and higher.
7.11.1 Basic setting
In order to activate the hydraulic functionality, the following two basic settings need
to be configured:
1. Chose the control mode via
P 300[0] - CON_CgfCon
: "TCON(1) = Torque
control / Hydraulic control" or "VFCON(0) = V/Hz mode”
Image 7.49: “Hydraulic basic settings” screen