11.6.32.3 Error 33-2 (emergency code 5300h)
Cause: Internal timing error
Suggested steps:
Please restart device.
Computational load in time-
critical task of axis module is
too high.
l
Please reduce computational load by
removing parameters from mapping.
l
De-activate features of control system or
motion control.
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
11.6.32.4 Error 33-3 (emergency code 5300h)
Cause: Unknown EXCEPTION in TC-safety
Suggested steps:
Reset device!
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
419
11 Alarms & warnings
11.6.32.5 Error 33-4 (emergency code 5300h)
Cause: Internal timing error
Suggested steps:
Run time error, not enough CPU performance, check PLC program
Computational load in time-
critical task of axis module is
too high.
l
Please reduce computational load by
removing parameters from mapping.
l
De-activate features of control system or
motion control.
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.