11.6.42.3 Error 45-2 (emergency code FF00h)
Cause:
Movement requested which was limited by reversing lock, limit switch or reference v
alue limitation. Lock active in both directions
Suggested steps:
Check plausibility of limit switches and/or software limits
The reference value violates
a lock or limit switch.
l
Please check reference values. If this axis is
working in cyclic synchronous mode, make a
scope record.
l
Check factor group settings.
l
Check mode of operation.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
437
11 Alarms & warnings
11.6.42.4 Error 45-3 (emergency code 8612h)
Cause: Software limit switch overtravel detected, traversing task rejected
Suggested steps:
Quit error and change reference value
The reference value violates
a lock or limit switch.
l
Please check reference values. If this axis is
working in cyclic synchronous mode, make a
scope record.
l
Check factor group settings.
l
Check mode of operation.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.