
11.6.29.2 Error 30-2 (emergency code 5300h)
Cause: Initialization error calculating motor torque constant
Suggested steps:
Check motor parameters
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
414
11 Alarms & warnings
11.6.29.3 Error 30-3 (emergency code 5300h)
Cause: Error while calculating flux model of asynchr. motor
Suggested steps:
Check motor parameters (Rrot, Lsig, Lmag) and magn.current Imag
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.