8.5.15 Method (33) and (34): with zero pulse
8.5.15.1 Method (33): Leftward travel direction
The zero pulse corresponds to the first zero pulse to the left.
Image 8.60: Homing with zero pulse
8.5.15.2 Method (34): Rightward travel direction
The zero pulse corresponds to the first zero pulse to the right.
Image 8.61: Homing with zero pulse
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
266
8 Motion profile
8.5.16 Method (35)
The actual position corresponds to the reference point.
Image 8.62: The actual position corresponds to the homing point