91
−
(Caution) Be careful as the start level of the function No. 92 is different from that of the other
function Nos.
The way of starting is given in the explanation of each function.
[Explanation of the contents of setting]
Function No. 21 Bank function setting
In these items, setting of the bank function operation is made.
The contents of setting for each item is described as follows :
Item 1 : Setting of with/without bank operation and number of banks
In this item, with/without bank function and number of banks are set.The number of banks
used means to set the number of patterns desired to be read in the memory of the sewing
machine side. Set values are 1 to 16. If “0” is set, the bank function does not work.
(2) How to use the bank function (Function No. 021 and 075)
Bank function
The bank function means that plural patterns
in the floppy disk can be stored in the memory
of the sewing machine main unit and instantly
change the patterns from the external signal
or operation panel and that plural patterns can
be sewn. (Refer to the right figure.)
[Setting to use the bank function]
To use the bank function, it is necessary to set some of the contents of the memory switch.
The necessary contents to be set are described as follows :
[Setting item when using the bank function]
When using the bank function, following setting of the memory switch is necessary :
As for the way of change of the memory switch, refer to the item “How to use the memory switch” P56.
Function No. of the memory switch which is necessary for setting.
Item
1
2
3
1
2
2
1
2
Remarks
Number of banks Effective/ineffective setting
Read-in method setting
Selection method setting
Number of selectable patterns
Start terminal number of signal for selection
Fixed retracted position setting
X fixed retracted position
Y fixed retracted position
Function
Bank function
Bank selection connection setting
Jog function
Coordinate of fixed retracted position
(Caution)
Function No.
21
75
3
92
Table 1
Read-in
FDD
Memories inside the
sewing machine
Read out the pattern by
operation of readout from
t h e e x t e r n a l s i g n a l ,
operation panel, etc.
Bank 1
Bank 2
Bank 3
Bank 4
Bank 5