102
−
Setting
FLIP
LATCH
Remarks
Description
The feeding frame is lowered only
when the pedal is depressed.
If the pedal is depressed for the first
time, the feeding frame is lowered,
and kept lowered even when the
pedal is released.
If the pedal is depressed for the
second, the feeding frame will be
raised.
Function No. 32 Pedal input control (1)
This function sets the way of pedal operation.
Item 1 : Sets the pedal operation of the pedal 1 (feeding frame, right).
Set value FLIP or LATCH (Refer to the table 4.) Initial setting :
Item 2 : Sets the pedal operation of the pedal 2 (feeding frame, left).
Set value FLIP or LATCH (Refer to the table 4.) Initial setting : LATCH (Solenoid type : Not used)
Item 3 : Sets the pedal operation of the pedal 3 (stroke presser 1).
Set value FLIP or LATCH (Refer to the table 4.) Initial setting : LATCH
(However, this function is not used with the LK-1930.)
Function No. 33 Pedal input control (2)
This function sets the way of pedal operation. (This function sets the continuation of the function No. 32.)
Item 1 : Sets the pedal operation of the pedal 4 (stroke presser 2).
Set value 0 or 1 (Refer to the table 4.) Initial setting : LATCH
(However, this function is not used with the LK-1930.)
[Explanation of the operations of the respective settings]
Table 4
Solenoid type : Non latch
Pneumatic type : Latch