(60) External input terminal connection setting 5 : This function is not used with the standard machine.
Function No. : 086
Function : Setting of the input device of the external input terminal
Item : 1 Input terminal 12 setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] The input device of the external input 12 is set to the terminal
number. By this setting, the signal input device of the external input
12 can be freely changed.
Item : 2 Input terminal 13 setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] The input device of the external input 13 is set to the terminal
number. By this setting, the signal input device of the external input
13 can be freely changed.
Item : 3 Input terminal 14 setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] The input device of the external input 14 is set to the terminal
number. By this setting, the signal input device of the external input
14 can be freely changed.
(61) External input terminal connection setting 6 : This function is not used with the standard machine.
Function No. : 087
Function : Setting of the input device of the external input terminal
Item : 1 Input terminal 15 setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] The input device of the external input 15 is set to the terminal
number. By this setting, the signal input device of the external input
15 can be freely changed.
Indication
Indication
Indication
Indication
(62) Pedal control 3
Supplementaly explanation : P.103
Function No. : 098
Function : Pedal operation mode is set.
Item : 1 Setting of pedal 1 operation active
(Set level 1)
HIGH
HIGH active (operates when switch is opened.) : Solenoid type : Initial setting
LOW
LOW active (operates when switch is closed.) : Pneumatic type : Initial setting
Item : 2 Setting of pedal 2 operation active
(Set level 1)
HIGH
HIGH active
LOW
LOW active : Initial setting
Item : 3 Setting of pedal 3 operation active
(Set level 1)
HIGH
HIGH active
LOW
LOW active : Initial setting
Indication
Indication
Indication
(63) Pedal control 4
Supplementaly explanation : P.103
Function No. : 099
Function : Pedal operation mode is set.
Item : 1 Setting of pedal 4 operation active
(Set level 1)
HIGH
HIGH active
LOW
LOW active : Initial setting
Indication