70
−
Indication
Indication
(24) Intermediate presser control
Function No. : 035
Function : Setting of the intermediate presser operation mode
Item : 1 Intermediate presser control
(Set level 1)
SEW
[Contents] Intermediate presser is operative. (The intermediate presser comes
down by the sewing data when the machine runs.) : Initial setting
TRIAL
[Contents] Intermediate presser is operative. (The intermediate presser comes down
by the sewing data both when the feed goes forward and backward.)
OFF
[Contents] Intermediate presser is inoperative and fixed at the lifting position.
(Set level 2)
Item : 2 Lowering timing
(Set level 1)
START
[Contents] The intermediate presser is lowered immeadiately before the sewing
machine starts. (The intermediate presser is lowered when the
sewing machine starts rotating.) : Initial setting
O. PRSR
[Contents] The intermediate presser is lowered simultaneously with the feeding
frame. (The intermediate presser comes down simultaneously when
the last feeding frame of the sequence of feeding frame is lowered.)
Indication
Indication
(25) Wiper control
Function No. : 036
Function : Wiper operation mode setting
Item : 1 Operation mode setting : Normally, use at the standard setting.
(Set level 2)
OFF
[Contents] Wiper operation is rendered ineffective.
Mg
[Contents] Signal of the magnet type wiper is rendered effective. : Initial setting
AIR
[Contents] Signal of the pneumatic type wiper is rendered effective.
Item : 2 Sweeping position setting
(Set level 2)
UNDER
[Contents] Below-sweeping (Wiper sweeps below the intermediate presser.) : This
function is operative when the optional side-sweeping wiper is used.
BETWEEN
[Contents] Above-sweeping (Wiper sweeps above the intermediate presser.)
: Initial setting
Item : 3 Sweeping position setting 2
(Set level 2)
UDET
[Contents] Wiper sweeps when the needle bar stops up.: Initial setting.
AUDET
[Contents] Wiper sweeps when the needle bar stops at the upper dead point.
It is possible when the main shaft stop position is set to its upper dead
point.
Indication
(26) Thread clamp control : This function is not used with the standard LK-1930.
Function No. : 037
Function : Wiper operation mode setting
Item : 1 Thread clamp control
(Set level 2)
OFF
[Contens] The thread clamp is made inoperative. : Initial setting
ON
[Contens] The thread clamp is made operative.
Item : 2 Thread clamp release operation timing
(Set level 2)
0 to 15
[Contens] The number of stitches to be sewn, from the state where the thread
clamp retains the needle thread to the point at which it releases the
thread, is specified. : Initial setting 0
Indication
Indication