139
−
15. TABLE OF ERROR INDICATION ( LK-1910, 1920)
Remarks
The service pattern is
registered in SYSTEM ROM.
For the pneumatic type only
Corrective measure
Check the pattern No.
Check the scale rate and sewing pitch.
Turn the hand pulley, and return the needle bar to the
upper position.
Check the pattern and scale rate.
•
Re-sewing by retreat of the feed
→
start
•
Thread trimming action using the temporary stop switch or
reset
•
Return-to-origin action by reset after thread trimming action
•
Turn OFF the power switch, and remove the cause of
trouble.
•
Check the power source voltage.
Check the mounting of EEP-ROM
(contact failure, direction of mounting, etc.).
• Retreat of the feed after threading and re-sewing
• Return-to-origin action by reset
Turn OFF the power switch, and check the air pressure.
Defective memory (Replace the MAIN circuit board.)
Defective MAIN circuit board
(Replace the MAIN circuit board.)
Turn OFF the power switch, and check whether the fan
filter is clogged, and the power source voltage. Turn ON
the power after the temperature has dropped properly.
Description
The specified pattern No. has not been
registered in the data ROM.
The sewing pitch is beyond 10 mm.
The needle bar is shifted from the upper
position.
The sewing area is beyond the limit.
Stop on the way while the sewing machine
is running.
The main shaft of the sewing machine does
not rotate due to some troubles.
The pattern data reading from the data
ROM cannot be made.
The needle thread has been broken during
sewing.
The air pressure is dropped.
The data writing to the memory for the
back-up cannot be made.
MAIN circuit board is uncontrollable due to
some troubles.
Temperature in the control box is
abnormally high.
Name of error
Pattern No. error
Enlargement error
Needle bar upper position
error
Sewing area over
Stop on the way
Machine lock error
Abnormal voltage error
Pattern data error
Needle thread breakage
detection error
Air pressure drop error
Memory write-in error
Time-out error
Overheat error
Error indication