68
−
(19) Feeding frame control 1
Complementary explanation
→
P.99
Function No. : 030
Function : Feeding frame device setting
Item : 1 Setting at the automatic opening/closing
(Set level 2)
0 to 99
[Contents] Action sequence is set when the feeding frame automatically opens/
closes in case of operating the preparation key, threading key, etc.
Initial setting “0”
Item : 2 Setting of opening/closing control at the time of pedal operation
(Set level 1)
0 to 99
[Contents] Action sequence is set when opening/closing the feeding frame at
the time of pedal operation. (Set level 1)
0 : Monolithic feeding frame
1 : Separate-type feeding frame Feeding frame can be lowered
from either right- or left-side.
2 : Separate-type feeding frame The right-side is prior. Feeding
frame can be lowered in the order of right- to left-side.
3 : Separate-type feeding frame The left-side is prior. Feeding frame
can be lowered in the order of the left- to right-side.
4 to 99 : Monolithic feeding frame
Item : 3 Setting of opening/closing control at the time of pedal operation when temporary stopping
(Set level 1)
0 to 99
[Contents] Action sequence is set when opening/closing the feeding frame at
the time of pedal operation when temporary stopping.
0 : Monolithic feeding frame
1 : Separate-type feeding frame Feeding frame can be lowered from
either right- or left-side.
2 : Separate-type feeding frame The right-side is prior. Feeding
frame can be lowered in the order of right- to left-side.
3 : Separate-type feeding frame The left-side is prior. Feeding frame
can be lowered from left- to right-side.
4 to 99 : Monolithic feeding frame
Indication
Indication
Indication
(20) Feeding frame control 2
Complementary explanation
→
P.101
Function No. : 031
Function : Feeding frame setting
Item : 1 Setting of the order of the feeding frame at the completion of the sewing
(Set level 2)
0 to 99
[Contents] Initial setting 0 (release at all times) : when item “RELEASE” setting only.
Item : 2 Setting of the action of the feeding frame at the completion of the sewing
(Set level 1)
ATSTART
[Contents] Feeding frame is opened after the completion of the sewing. (After
moving to the sewing start point, the feeding frame is opened and
waits.) : Initial setting
HOLD
[Contents] Feeding frame is not opened after the completion of the sewing.
(After moving the sewing start point, the feeding frame is kept
lowered and waits. It is opened by pedal operation.)
ATEND
[Contents] Feeding frame is opened immediately after the completion of the
sewing. (After the completion of the sewing, the feeding frame is
opened and moves to the sewing start point.)
Item : 3 Setting of the constant lowering of the feeding frame
(Set level 1)
OFF
[Contents] Constant lowering action is rendered ineffective. : Initial setting
ON
[Contents] Constant lowering action is rendered effective. Feeding frame is in the
lowering state at all times, and is not operative by the pedal operation.
Indication
Indication