117
−
OUTPUT CHECK
0 00000000
(2)-3 Function No. 3 : Output check function
Operation of the devices can be confirmed by outputting signals to the respective outputs from operation
panel.
1) Select the
key when selection of the test mode is
shown.
[Display indication]
1
Step indication Output check is composed of four steps from
0 to 3.
The current step is shown.
2
Input state is shown “0” or “1”.
Indication digit changes according to the respective steps.
When the indication is “1”, the signal is being output.
2) When depressing the feeding frame switch, the step indication of indication
1
is updated.
By pressing the keys from
to
, the keys output signals to the respective output terminals.
[Indication on the dispaly]
™
Step “0”
Output check of air system (No output with the magnet type machine head)
™
Step “1”
Output signal of magnet components is output.
™
Step “2”
™
Step “3”
Output when the optional is attached (Standard type machine does not work.)
*
*
*
*
Wiper Output by “ ” key
Feeding frame Output by “ ” key
Intermediate presser Output by “ ” key
TENSION DISK Output by “ ” key
*
*
*
*
*
*
*
*
Feeding frame 1 Output by “ ” key
Feeding frame 2 Output by “ ” key
Not used
External output 1 Output by “ ” key
External output 2 Output by “ ” key
External output 3 Output by “ ” key
External output 4 Output by “ ” key
External output 5 Output by “ ” key