– 165 –
2-A)
Improperly connected J20 and J21
connectors
3-A)
Improperly connected J14 and J15
connectors
2-A)
Fuse F1 or F2 has blown.
1-A)
Disconnected J16 connector (LK-1930)
1-B)
Disconnected J59 connector
20.
After turning ON the power, the machine moves
in a wrong direction at the first origin retrieval.
2
1
.
Even when turning ON the power, the machine
entirely fails to work.
22.
Others
(The machine does not operate normally.)
23.
In case of the magnet type, the origin retrieval is
made while the feedin frame is kept raised. After
the origin retrieval is made, the feeding frame
comes down. (For LK-1930 only)
24.
Fan alarm cannot be released. (LK-1930)
"EH" (overheat error) cannot be released.
(LK-1910/20)
Return the memory switch to the initial condition.
Check the connection of the connectors.
Check the connection of the connectors.
Return the memory switch to the initial condition.
Replace the blown fuse after removing the cause. (10A)
Replace the MAIN, POWER or PMDC circuit board.
Return the memory switch to the initial condition.
Replace the PMDC, MAIN, POWER or SERVO circuit board.
Set the memory switch to the magnet type by initializing the
memory switch.
Securely connect the connector.
Securely connect the connector.
Troubles
Cause (1)
Cause (2)
Checking order and adjusting method
20-1)
Sewing machine model setting is improper.
(For LK-1930 only)
20-2)
MAIN circuit board
←→
X, Y sensor have
not been correctly connected.
20-3)
MAIN circuit board
←→
X, Y motor have
not been correctly connected.
21-1)
Sewing machine model setting is improper.
21-2)
The main power is not supplied.
21-3)
Defective circuit board
22-1)
The machine operation mode is improper.
22-2)
Defective circuit board
23-1)
Memory switch setting is for the pneumatic
type.
24-1)
Thermostat
←→
MAIN circuit board are not
connected.