76
−
(43) Intermediate presser connection setting : This function is not used with the standard machine.
Function No. : 065
Function : Setting of the output device of the drive signal of intermediate presser lifter
Item : 1 Intermediate presser lifter setting
(Set level 2)
0
[Contents] No connection
1 to 16
[Contents] Output of the intermediate presser lifter is set to the terminal
number. By this setting, the signal output device of the intermediate
presser lifter can be freely changed. : Initial setting 3
Item : 2 Setting of the actuator of adjusting the height of intermediate presser This function is not used with
LK-1930. (Set level 2)
0
[Contents] No connection
1 to 16
[Contents] Output of the device for adjusting the height of intermediate presser
is set to the terminal number. By this setting, the signal output device
of the device for adjusting the height of intermediate presser can
be freely changed. : Initial setting 4
Item : 3 Setting of the output at the time of start
(Set level 2)
LOW
[Contents] Active LOW output (When the power is ON, the presser goes up
when the presser signal is in the low level.) : Initial setting
HIGH
[Contents] Active HIGH output (When the power is ON, the presser goes up
when the presser signal is in the high level.)
Indication
Indication
Indication
(44) Wiper and thread clamp connection setting : This function is not used with the standard machine.
Function No. : 066
Function : Setting of the output device of the drive signal of wiper and thread clamp
Item : 2 Wiper setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Output of the feeding frame is set to the terminal number. By this
setting, the signal output device of the wiper can be freely changed.
Item : 3 Thread clamp setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Output of the thread clamp is set to the terminal number. By this
setting, the output device of output signal of the thread clamp can
be freely changed.
(45) Inverting clamp connection setting : Use this function without changing the standard setting.
Function No. : 069
Function : Setting of the output device of the drive signal of the inverting clamp
Item : 1 Inverting device setting
(Set level 2)
0
[Contents] No connection
1 to 16
[Contents] Output of the inverting clamp is set to the terminal number. By this
setting, the signal output device of the inverting clamp can be freely
changed. : Initial setting 5
Indication
Indication
Indication