77
−
Indication
Indication
(47) Tension controller No. 3 connection setting : Use this function without changing the standard setting.
Function No. : 073
Function : Setting of the output device of the drive signal of tension controller No. 3
Item : 1 Setting of the drive device
(Set level 2)
0
[Contents] No connection
1 to 16
[Contents] The output device of tension controller No. 3 is set to the terminal
number. By this setting, the signal output device of the tension
controller No. 3 can be freely changed. : Initial setting 6
(48) Material end detection device connection setting : This function is not used with the standard machine.
Function No. : 074
Function : Setting of the input device of the signal of material end detection device.
Item : 1 Material end detection sensor
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] The input device of material end detection signal is set to the
terminal number. By this setting, the signal input device of the
material end detection device can be freely changed.
Indication
Indication
Indication
(46) Bobbin thread replacing device connection setting : Not used.
Function No. : 072
Function : Setting of the output/input devices of the bobbin thread replacing device
Item : 1 Setting of the signal output of the start of replacement
(Set level 2)
0
[Contents] No connection : Initital setting
1 to 16
[Contents] Output device of the signal of the start of replacement is set to the
terminal number. By this setting, output signal device of the signal
of the start of replacement can be freely changed.
Item : 2 Setting of the input of the signal during the replacement
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Input device of the signal during the replacement is set to the
terminal number. By this setting, the input device of the signal during
the replacement can be freely changed.
Item : 3 Setting of the error detection signal input
(Set level 2)
0
[Contents] No connection (Error detection is not made.) : Initial setting
1 to 16
[Contents] Input device of the signal of error occurring is set to the terminal
number. By this setting, the input device of the signal of error
occurring can be freely changed.