ADU Error Messages
D-18
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Storage enclosure on SCSI
bus
X
indicated an overheated
condition.
SOLUTION: Make sure all
cooling fans are operating
properly. Also be sure the
operating environment of
storage enclosure is within
temperature specifications.
The external storage unit is
generating a temperature alert.
1. Be sure that all fans are
connected and operating
properly.
2. Be sure that the operating
environment of the
storage unit is within
specifications.
3. For better airflow, remove
any dust buildup from fans
or other areas.
4. Check your server-
specific user
documentation for
allowable temperature
specifications and
additional tips.
5. If none of the previous
steps solve this problem,
replace the fan.
Storage enclosure on SCSI
bus
X
is unsupported with its
current firmware version.
SOLUTION: Upgrade the
firmware version on the
storage enclosure.
The firmware version of the
external storage unit is not
supported.
Upgrade the firmware.
Storage enclosure on SCSI
bus
X
indicated that the fan
failed.
SOLUTION: Replace the fan.
The cooling fan located in the
external storage unit has
experienced a failure.
Replace the fan.
continued