POST Error Messages
C-42
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-12: 1600 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1611-Slot Fan Failure
Detected
None
Required fan not
spinning.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-System Fan
failure detected
None
Required fan not
spinning.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-System Fan not
present
None
Required fan not
installed.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1612-Primary power
supply failure.
2 short
Primary power supply
has failed.
Replace power supply as
soon as possible.
1613-Low System
Battery.
None
Real-time clock system
battery is running low on
power.
Replace battery (or add
external battery) as soon as
possible.
1614- Redundant Fan
Failure
None
Fan is not spinning.
1. Check fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1615-Power Supply
Configuration Error
None Your
configuration
requires an additional
power supply. A moving
bar is displayed,
indicating that the system
is waiting for another
power supply to be
installed.
Install the additional power
supply.
continued