Test Error Codes
B-4
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
Table B-3: Memory Test Error Codes
continued
Error Code
Description
Recommended Action
203-
XX
Memory write/read test
failed
204-
XX
Memory address test
failed
205-
XX
Walking I/O test failed
206-
XX
Increment pattern test
failed
The following steps apply to error codes 203-
XX
through 206-
XX
:
1. Replace the memory module and retest.
2. Replace the processor and retest.
3. Replace the memory expansion board and retest.
207-
XX
Invalid
memory
configuration; check DIMM
installation. DIMMs
installed have 8K refresh
Replace memory modules.
208-
XX
Invalid memory detected;
check DIMM installation
Be sure that the memory is installed. Then, refer to
your server-specific user documentation for supported
memory and replace memory modules as indicated.
210-
XX
Random pattern test failed
1. Replace the memory module and retest.
2. Replace the processor and retest.
3. Replace the memory expansion board and retest.
0211-01
RAND test failed
0211-02
Error while saving test
block
0211-03
Error while restoring test
block
0211-04
Insufficient memory to
perform test
0211-05
Failed inverted pattern
compare, but RAM was
correct
0212-01
RAM long test failed
0212-02
Error while saving test
block
The following steps apply to error codes 0211-01
through 0214-89:
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
3. Replace the memory expansion board and retest
continued