ADU Error Messages
HP Servers Troubleshooting Guide
D-9
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Drive Monitoring features are
unobtainable.
ADU is unable to get monitor
and performance data due to
fatal command problem (such
as drive time-out), or is unable
to get data due to these
features not being supported
on the controller.
Check for other errors such as
time-outs. If no other errors
occur, upgrade the firmware to
a version that supports monitor
and performance, if desired.
Drive Monitoring is NOT
enabled for SCSI Port
X
Drive ID
Y
.
The monitor and performance
features have not been
enabled on this drive.
Run the server setup utility to
initialize the monitor and
performance features.
Drive time-out occurred on
physical drive bay
X
.
ADU issued a command to a
physical drive and the
command was never
acknowledged.
The drive or cable may be
bad. Check the other error
messages on the
Diagnostics
screen to determine resolution.
Drive
X
indicates position
Y
.
Message indicates a
designated physical drive,
which seems to be scrambled
or in a drive bay other than the
one for which it was originally
configured.
Examine the graphical drive
representation on ADU to
determine proper drive
locations. Remove drive
X
and
place it in drive position
Y
.
Rearrange the drives
according to the ADU
instructions.
Duplicate write memory error.
Data cannot be written to the
array accelerator board in
duplicate due to the detection
of parity errors. This is not a
data-loss situation.
Replace the array accelerator
board.
Error occurred reading RIS
copy from SCSI Port
X
Drive
ID.
An error occurred while ADU
was trying to read the reserve
information sector (RIS) from
this drive.
HP stores the hard drive
configuration information in the
RIS. If there are multiple
errors, this drive may need to
be replaced.
FYI: Drive (bay)
X
is
non-Compaq supplied.
Compaq did not supply the
installed drive.
If problems exist with this
drive, replace it with a
supported drive.
continued