ADU Error Messages
D-4
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Accelerator status: Obsolete
data was discarded
During reset initialization,
obsolete data was found in the
cache, and was discarded (not
written to the drives).
Normal operations should
continue.
Accelerator status: Obsolete
data was flushed (written) to
drives
During reset initialization,
obsolete data was found in the
cache. The obsolete data was
written to the drives, but newer
data may have been
overwritten.
If newer data was overwritten,
you may need to restore
newer data; otherwise, normal
operation should continue.
Accelerator status:
Permanently disabled
Array accelerator board has
been permanently disabled. It
will remain disabled until it is
reinitialized using the Array
Configuration Utility (ACU).
Check the Disable Code field.
Run ACU to reinitialize the
array accelerator board.
Accelerator status: Possible
data loss in cache
Possible data loss was
detected during power-up due
to all batteries being below
sufficient voltage level and no
presence of the identification
signatures on the array
accelerator board.
There is no way to determine if
dirty or bad data was in the
cache and is now lost.
Accelerator status:
Temporarily disabled
Array accelerator board has
been temporarily disabled.
Check the Disable Code field.
Accelerator status:
Unrecognized status
A status returned from the
array accelerator board that
ADU does not recognize.
Obtain the latest version of
ADU.
Accelerator status: Valid data
found at reset
Valid data was found in
posted-write memory at
reinitialization. Data will be
flushed to disk.
There is no error or data loss
condition. No action is
necessary.
Accelerator status: Warranty
alert
Catastrophic problem with
array accelerator board. Refer
to other messages on
Diagnostics screen for exact
meaning of this message.
Replace the array accelerator
board.
continued