ADU Error Messages
D-16
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
SCSI Port
X
, Drive
ID
Y
…S.M.A.R.T. predictive
failure errors Have been
detected in the factory Monitor
and Performance data.
SOLUTION: Please replace
this drive when conditions
permit.
A predictive failure warning for
this hard drive has been
generated, indicating that a
drive failure is imminent.
Replace this drive at the
earliest opportunity.
Refer to “SCSI Hot-Plug Hard
Drives” in Chapter 2 before
performing this operation.
SCSI Port
X
, Drive
ID
Y
…S.M.A.R.T. predictive
failure errors Have been
detected in the since power
Monitor and Performance
data.
SOLUTION: Please replace
this drive when conditions
permit.
A predictive failure warning for
this hard drive has been
generated, indicating a drive
failure is imminent.
Replace this drive at the
earliest opportunity.
Refer to “SCSI Hot-Plug Hard
Drives” in Chapter 2 before
performing this operation.
SCSI Port
X
, Drive ID
Y
was
replaced on a good volume:
(failure message)
ADU found this drive was
replaced, even though there
was no problem with the
volume.
No action needs to be taken.
Set configuration command
issued
The configuration of the array
controller has been updated.
The array accelerator board
may remain disabled until it is
reinitialized.
Run the server setup utility to
reinitialize the array
accelerator board.
Soft Firmware Upgrade
required
ADU has determined that your
controller is running firmware
that has been soft upgraded
by the Upgrade Utility.
However, the firmware running
is not present on all drives.
This could be caused by the
addition of new drives in the
system.
Run the Upgrade Utility to
place the latest firmware on all
drives.
continued