POST Error Messages
C-30
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
800 Series POST Error Messages
Table C-9: 800 Series POST Error Messages
Error Code
Audible
Beeps
Probable Source of
Problem
Action
800-Server Feature
Board must be
installed in slot 1 for
proper operation
None
The system has detected
the absence of the
Server Feature Board.
The Server Feature
Board is not installed in
the proper slot.
The Server Feature
Board does not match
this system.
1. Install the Server Feature
Board in PCI slot 1.
2. Reseat the Server
Feature Board.
3. Be sure that the Server
Feature Board is from
this system.
801-Server Feature
Board is not properly
cabled to the system.
Verify that the server
management
information cable from
the system board to
the Server Feature
Board in slot 1 is
intact and fully
secured at both ends
None
The system has detected
that the server-
management information
cable is not properly
installed.
1. Be sure that a server-
management information
cable is installed in the
system.
2. Inspect the server-
management information
cable for signs of
damage.
3. Reseat the server-
management information
cable on the system
board and on the Server
Feature Board.
continued