POST Error Messages
C-44
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-12: 1600 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1618-AC Line is not
cord redundant
None
AC line cord redundancy
is not achieved.
AC line cord redundancy is
not necessary for the server
to operate. If AC line cord
redundancy is wanted, plug
server into two separate
AC sources. Each AC source
should be on a different
power grid/circuit.
1619-Maximum
Power Usage was
exceeded
None
System has reached the
maximum power draw for
the current power
configuration of the
server.
1. If running on a 110-volt
AC source, switch to
220-volt.
2. Add an extra power
supply/SPM pair.
3. Decrease the options in
the system. Refer to the
power calculator on the
Web for power
considerations:
activeanswers.compaq.com/
aaconfigurator
1619- Server
management board is
in the wrong slot
None
The server management
board is not in the proper
location.
Install the server
management board in the
correct slot.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None
SCSI bus failure
detected.
Be sure that the integrated
SCSI controller has SCSI
termination connected.
1620-Fan Not Present
None
Fans are missing or not
cabled correctly.
For the system to function, it
needs the fans described in
the server-specific
maintenance and service
guide.
Be sure that the fans are
present and installed
correctly.
continued