Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1777-Slot
X
Drive
Array – ProLiant Drive
Storage Enclosure
Problem Detected
(followed by one or
more of the following):
SCSI Port
Y
: Cooling
Fan Malfunction
Detected
SCSI Port
Y
:
Overheated Condition
Detected
SCSI Port
Y
:
Side-Panel must be
Closed to Prevent
Overheating
SCSI Port
Y
:
Redundant Power
Supply Malfunction
Detected
SCSI Port
Y
: Wide
SCSI Transfer Failed
SCSI Port
Y
: Interrupt
Signal Inoperative
SCSI Port y:
Unsupported ProLiant
Storage System
Detected
None Environment
threshold
was violated on the drive
enclosure.
Check cooling fan operation
by placing hand over fan. Be
sure that internal plenum
cooling fan in tower servers or
storage systems is
operational. If fan is not
operating, check for
obstructions and check all
internal connections. Replace
unit side panel if removed.
If the ProLiant Storage
System power LED is amber
instead of green, this
indicates a redundant power
supply failure.
Check SCSI cables. If the
message indicates to check
SCSI cables, compare your
cabling against the diagrams
in your HP Smart Array
Controller user guide. If the
routing is correct, replace
cables on the specified port
until the POST message is
eliminated.
1778-Drive Array
resuming Automatic
Data Recovery
process
None
This message is
displayed whenever a
controller reset or power
cycle occurs while
Automatic Data Recovery
is in progress.
No action necessary.
continued