ADU Error Messages
D-10
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Identify controller data did not
match with NVRAM.
The controller identification
data from the array controller
does not match with the
information stored in NVRAM.
This can occur if new,
previously configured drives
are placed in a system that
has also been previously
configured. It can also occur if
the firmware on the controller
has been upgraded and the
server setup utility was not.
Run the Inspect Utility to check
the controller identification
data. If the firmware version
field is the only difference
between the controller and
NVRAM data, this is not a
problem. Otherwise run the
server setup utility.
Identify logical drive data did
not match with NVRAM.
The identify unit data from the
array controller does not
match with the information
stored in NVRAM. This can
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured.
Run the server setup utility to
configure the controller and
NVRAM.
Insufficient adapter resources
The adapter does not have
sufficient resources to perform
posted-write operations to the
array accelerator board. Drive
rebuild may be occurring.
Operate the system without
the array accelerator board
until the drive rebuild
completes.
Inter-controller link connection
could not be established
Unable to communicate over
the link connecting the
redundant controllers.
Be sure that both controllers
are using the same hardware
and firmware revisions. If one
controller failed, replace it.
Less than 75% batteries at
sufficient voltage
The operation of the array
accelerator board has been
disabled due to less than 75%
of the battery packs being at
the sufficient voltage level.
Allow sufficient time for the
batteries to recharge (36
hours). If the batteries have
not recharged after 36 hours,
replace the array accelerator
board.
continued