POST Error Messages
HP Servers Troubleshooting Guide
C-55
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1757 - Array
Accelerator
Daughterboard
incompatible with this
model controller
None
4-MB array accelerator
board installed on Smart
Array 42
XX
Controller.
Replace 4-MB array
accelerator board with a
16-MB or 64-MB board.
1758- Drive Array -
Accelerator Size
Mismatch Between
Controllers 64MB
Array Accelerator
should be attached to
both controllers. Array
Accelerator is
temporarily disabled.
None
Redundant Smart Array
4250ES Controller pair
with incorrect array
accelerator installed.
Install 64-MB array
accelerator module on both
Smart Array 4250ES
Controllers.
1759-Slot z Drive
Array – Redundant
Controller Error
None Redundant
controller
problem.
Replace or reseat controllers.
May also be caused by a
defective system board.
1760-Fixed Disk
X
does not support
Block Mode
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1761-Fixed Disk 1
does not support
Block Mode
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1762-Redundant
controller operation is
not supported in this
firmware version.
None
Old firmware on
controller (does not
support redundant-
controller operation).
Upgrade controller firmware
using Options ROMPaq.
1763- Array
Accelerator
daughtercard is
detached; please
reattach.
None
Array accelerator module
is loose, missing, or
defective.
Replace array accelerator
module, or reseat if connector
is not fully mated.
continued