Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Controller reported POST
error.
Error Code:
X
The controller returned an
error from its internal
Power-On Self-Test (POST).
Replace the controller.
Controller restarted with a
signature of zero
ADU did not find a valid
configuration signature to use
to get the data. NVRAM may
not be present (unconfigured)
or the signature present in
NVRAM may not match the
signature on the controller.
Run the server setup utility to
configure the controller and
NVRAM.
Disable command issued
The issuing of the Accelerator
Disable command has
disabled posted-writes. This
occurred because of an
operating system device
driver.
Restart the system. Run ACU
to reinitialize the array
accelerator board.
Drive (bay)
X
firmware needs
upgrading
Firmware on this physical drive
is below the latest
recommended version.
Run the Options ROMPaq
Utility to upgrade the drive
firmware to the latest revision.
Drive (bay)
X
has insufficient
capacity for its configuration
Drive has insufficient capacity
to be used in this logical drive
configuration.
Replace this drive with a larger
capacity drive.
Drive (bay)
X
has invalid M&P
stamp
Physical drive has invalid
monitor and performance data.
Run the server setup utility to
properly initialize this drive.
Drive (bay)
X
has loose cable
The array controller could not
communicate with this drive at
power-up. This drive has not
previously failed.
Check all cable connections
first. The cables could be bad,
loose, or disconnected. Power
up the system and attempt to
reconnect data/power cable to
the drive. If this does not work,
replace the cable. If still not
successful, the drive may need
to be replaced.
continued