Test Error Codes
HP Servers Troubleshooting Guide
B-9
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
Table B-7: Diskette Drive Test Error Codes
continued
Error Code
Description
Recommended Action
609-
XX
Diskette
reset
controller
test failed
610-
XX
Diskette change line test
failed
699-
XX
Diskette drive/media ID
error
1. Replace the media and retest.
2. Run the server setup utility and retest.
1100-1199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial interface
board or system board functions. Corrective action may require replacement of the
serial/parallel interface board or the system board assembly.
Table B-8: Serial Test Error Codes
Error Code
Description
Recommended Action
1101-
XX
Serial port test failed
1109-
XX
Clock register test failed
The following steps apply to error codes 1101-
XX
and
1109-
XX
:
1. Check the switch settings on the serial/parallel
interface board (if applicable) and retest.
2. Replace the serial/parallel interface board (if
applicable) and retest.
3. Replace the system board and retest.