POST Error Messages
HP Servers Troubleshooting Guide
C-53
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1728-Drive Array-
Abnormal Shut-Down
Detected With Write-
Cache
None
There is no array
accelerator battery
backup on this array
controller but caching
was enabled. Any data
that may have been in
array accelerator memory
has been lost due to the
controller power loss.
Restore data from backup.
1729-Slot 1 Drive
Array – Performance
Optimization Scan In
Progress.
RAID 4/5/ADG
performance may be
higher after
completion.
None
RAID 4/5/ADG parity
drive(s) are being
initialized.
This message is normal
following the initial
configuration of RAID 4 or
RAID 5 logical drives.
Performance of the controller
improves after the parity data
has been initialized by ARM
(an automatic process that
runs in the background on the
controller).
1730-Fixed Disk 0
does not support
DMA Mode
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1731-Fixed Disk 1
does not support
DMA Mode.
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1740-Fixed Disk 0
failed Set Block Mode
command
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1741-Fixed Disk 1
failed Set Block Mode
command
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1750- Fixed Disk
X
failed ID command
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1750-Fixed Disk
X
failed Identify
command
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
continued