Diagnostic Tools
HP Servers Troubleshooting Guide
4-17
HP CONFIDENTIAL
Writer: Ted Weiman File Name: e-ch4 Diagnostic Tools.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:36 AM
Table 4-1: Event Messages
continued
Event Message
Event Type
Action
System AC Power
Overload (Power
Supply
X
)
Power supply overload
Switch the voltage
from 110 V to 220 V or
add an additional
power supply (if
applicable to your
system).
If the problem is still
not resolved, remove
some of the options
installed.
Operating System
Blue Screen Trap:
Cause [NT]
Kernel Panic: Cause
[UNIX]
Abnormal Program
Termination: Cause
[NetWare]
System lockup
Refer to the
documentation for your
operating system.
Automatic Operating
System Shutdown
Initiated Due to Fan
Failure
Fan failure
Replace fan.
Automatic Operating
System Shutdown
Initiated Due to
Overheat Condition
Fatal Exception
(Number
X
, Cause)
Overheat condition
Check fans. Also, be
sure that the server is
properly ventilated and
that the room is set
within the required
temperature range.