POST Error Messages
HP Servers Troubleshooting Guide
C-63
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1785-Slot
X
Drive
Array not Configured
(followed by one of
the following):
(1) Run Compaq
Array Configuration
Utility
(2) No drives detected
(3) Drive positions
appear to have
changed – Run Drive
Array Advanced
Diagnostics if
previous positions are
unknown. Then turn
system power OFF
and move drives to
their original
positions.
(4) Configuration
information indicates
drive positions
beyond the capability
of this controller. This
may be due to drive
movement from a
controller that
supports more drives
than the current
controller.
(5) Configuration
information indicates
drives were
configured on a
controller with a
newer firmware
version.
None
Drive array configuration
not detected.
1. Run the Array
Configuration Utility.
2. Turn off system and
check SCSI cable
connections to be sure
that drives are connected
properly.
3. Run Array Diagnostic
Utility if previous
positions are unknown.
Then, turn system power
off and move drives to
their original positions.
4. To avoid data loss,
reconnect drives to the
original controller or
upgrade the controller
firmware to the version
on the original controller
(or higher) using Option
ROMPaq.
continued