POST Error Messages
C-58
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1770-Slot
X
Drive
Array – SCSI Drive
Firmware Update
Recommended –
Please upgrade
firmware on the
following drive(s)
using Options
ROMPaq (available
from
www.compaq.com):
SCSI Port
Y
SCSI
ID
Z
None
Drive firmware update
needed.
The indicated drives are
running firmware that is
known to cause intermittent
problems. Use the Options
ROMPaq utility to upgrade
firmware on all drives to the
latest revision.
Download it from the following
website:
www.compaq.com/support
1771-Primary Disk
Port Address
Assignment Conflict
None
Internal and external hard
drive controllers are both
assigned to the primary
address.
Run the server setup utility
and correct.
1772-Secondary Disk
Port Address
Assignment Conflict
None Address
assignment
conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the server setup utility
and correct.
1773-Primary Fixed
Disk Port Assignment
Conflict
None
Fixed disk drive error
detected.
Run the server setup utility
and correct.
1774-Slot
X
Drive
Array – Obsolete data
found in Array
Accelerator.
None
Drives were used on
another controller and
reconnected to the
original controller while
data was in the original
controller cache.
Data found in array
accelerator is older than data
found on drives and has
automatically been discarded.
Check file system to
determine whether any data
has been lost.
continued