ADU Error Messages
HP Servers Troubleshooting Guide
D-17
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Storage enclosure on SCSI
bus
X
has a cabling error (bus
disabled).
SOLUTION: The SCSI
controller has an internal and
external cable attached to the
same bus. Please disconnect
the internal or external cable
from the controller. If this
controller supports multiple
buses, the cable disconnected
can be reattached to an
available bus.
The current cabling
configuration is not supported.
Refer to your server-specific
user documentation for cabling
guidelines, and reconfigure as
indicated.
Storage enclosure on SCSI
bus
X
indicated a door alert.
SOLUTION: Be sure that the
storage enclosure door is
closed or the side panel is
properly installed.
The side panel of the external
storage unit is open.
Be sure that the side panel of
the storage unit is securely
closed.
Storage enclosure on SCSI
bus
X
indicated a power
supply failure.
SOLUTION: Replace the
power supply.
A power supply in the external
storage unit has failed.
Replace the power supply.