Test Error Codes
HP Servers Troubleshooting Guide
B-5
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
Table B-3: Memory Test Error Codes
continued
Error Code
Description
Recommended Action
0212-03
Error while restoring test
block
0212-89
ECC error during testing
0214-01
Data error during test
0214-89
ECC error during testing
215 Non-functioning
DC-DC
converter for processor
X
Replace the Processor Power Module (PPM).
300-399, Keyboard Test Error Codes
The 300 series of diagnostic error codes identifies failures with keyboard and system
board functions. Corrective action may require replacement of the keyboard or the
system board assembly.
Table B-4: Keyboard Test Error Codes
Error Code
Description
Recommended Action
301-
XX
Keyboard short test, 8042
self-test failed
302-
XX
Keyboard long test failed
303-
XX
Keyboard LED test, 8042
self-test failed
304-
XX
Keyboard typematic test
failed
The following steps apply to error codes 301-
XX
through 304-
XX
:
1. Check the keyboard connection. If it is
disconnected, turn off the computer, connect the
keyboard, and then retest.
2. Replace the keyboard and retest.