ADU Error Messages
D-14
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Other controller indicates
different cache size
The other controller in the
redundant controller
configuration has a different
size array accelerator.
Be sure that both controllers
are using the same capacity
array accelerator.
RIS copies between drives do
not match
The drives on this controller
contain copies of the reserve
information sector (RIS) that
do not match.
The hard drives in the array do
not have matching
configuration information. To
remedy this:
1. Resolve all other errors
encountered.
2. Obtain the latest version
of ADU, and then rerun
ADU.
3. If unconfigured drives
were added, configure
these drives using ACU,
which should resolve the
error.
4. If drives or arrays were
moved, be sure that the
movement adheres to the
guidelines listed in the
documentation for the
array controller.
5. If the error persists after
completing steps 1
through 4, contact an
authorized service
provider.
SCSI Port
X
Drive ID
Y
failed –
REPLACE
(failure message)
ADU detected a drive failure.
Correct the condition that
caused the error, if possible, or
replace the drive.
SCSI port
X
, Drive ID
Y
firmware needs upgrading
Drive firmware may cause
problems and should be
upgraded.
Run Options ROMPaq to
upgrade the drive firmware to
a later revision.
continued