Rev. 1.0, 09/02, page 118 of 568
9. Each time a TGRA compare match occurs, the next output value is transferred to NDR and the
set value of the next output trigger period is transferred to TGRA. The activation source TGFA
flag is cleared.
10. When the specified number of transfers are completed (the TPU transfer CRA value is 0), the
TGFA flag is held at 1, the DTCE bit is cleared to 0, and a TGIA interrupt request is sent to the
CPU. Termination processing should be performed in the interrupt handling routine.
8.7.3 Software
Activation
An example is shown in which the DTC is used to transfer a block of 128 bytes of data by means
of software activation. The transfer source address is H
′
1000 and the destination address is
H
′
2000. The vector number is H
′
60, so the vector address is H
′
04C0.
1. Set MRA to incrementing source address (SM1 = 1, SM0 = 0), incrementing destination
address (DM1 = 1, DM0 = 0), block transfer mode (MD1 = 1, MD0 = 0), and byte size (Sz =
0). The DTS bit can have any value. Set MRB for one block transfer by one interrupt (CHNE =
0). Set the transfer source address (H
′
1000) in SAR, the destination address (H
′
2000) in DAR,
and 128 (H
′
8080) in CRA. Set 1 (H
′
0001) in CRB.
2. Set the start address of the register information at the DTC vector address (H
′
04C0).
3. Check that the SWDTE bit in DTVECR is 0. Check that there is currently no transfer activated
by software.
4. Write 1 to the SWDTE bit and the vector number (H
′
60) to DTVECR. The write data is H
′
E0.
5. Read DTVECR again and check that it is set to the vector number (H
′
60). If it is not, this
indicates that the write failed. This is presumably because an interrupt occurred between steps
3 and 4 and led to a different software activation. To activate this transfer, go back to step 3.
6. If the write was successful, the DTC is activated and a block of 128 bytes of data is transferred.
7. After the transfer, an SWDTEND interrupt occurs. The interrupt handling routine should clear
the SWDTE bit to 0 and perform other wrap-up processing.
8.8 Usage
Notes
8.8.1
Module Stop Mode Setting
DTC operation can be disabled or enabled using the module stop control register. The initial
setting is for DTC operation to be enabled. Register access is disabled by setting module stop
mode. Note that module stop mode cannot be set during DTC being activated. For details, refer to
section 21, Power-Down Modes.
Содержание H8S/2627
Страница 22: ...Rev 1 0 09 02 page xx of xxxvi Index 565 ...
Страница 30: ...Rev 1 0 09 02 page xxviii of xxxiv ...
Страница 36: ...Rev 1 0 09 02 page xxxiv of xxxiv Table 23 9 Flash Memory Characteristics 561 ...
Страница 82: ...Rev 1 0 09 02 page 46 of 568 ...
Страница 88: ...Rev 1 0 09 02 page 52 of 568 ...
Страница 98: ...Rev 1 0 09 02 page 62 of 568 ...
Страница 156: ...Rev 1 0 09 02 page 120 of 568 ...
Страница 390: ...Rev 1 0 09 02 page 354 of 568 ...
Страница 480: ...Rev 1 0 09 02 page 444 of 568 ...
Страница 512: ...Rev 1 0 09 02 page 476 of 568 ...
Страница 527: ...Rev 1 0 09 02 page 491 of 568 21 8 5 Writing to MSTPCR MSTPCR should only be written to by the CPU ...
Страница 528: ...Rev 1 0 09 02 page 492 of 568 ...
Страница 580: ...Rev 1 0 09 02 page 544 of 568 ...