Device Compliance Statement
Appx. 12 Device Compliance Statement
"Information on compliance to standards" based on the IEEE 488.2 standard
Item
Description
1
IEEE 488.1 interface functions
See “GP-IB specifications” in the Communications Instruction
Manual on the bundled LCR Application Disc.
2
Operation with a device address other
than 0 through 30
Such a setting is not possible.
3
Timing of changed device address recog
-
nition
A change of address is recognized immediately after changing.
4
Device settings at power on
The explanatory status information for hardware settings will be
cleared when the instrument is turned on. Otherwise, data is
backed up.
However, the header on/off setting, and response message sepa
-
rator and terminator are all reinitialized.
5
List of message exchange options
•
Input buffer capacity and operation
(See the bundled LCR Application Disc.)
Queries to which multiple response message instruments are
returned
:BIN:FLIMit:ABSolute?
......................................................2
:BIN:FLIMit:DEViation?
....................................................2
:BIN:FLIMit:PERcent?
........................................................2
:BIN:SLIMit:ABSolute?
......................................................2
:BIN:SLIMit:DEViation?
....................................................2
:BIN:SLIMit:PERcent?
........................................................2
:COMParator:FLIMit:ABSolute?
.......................................2
:COMParator:FLIMit:DEViation?
.....................................3
:COMParator:FLIMit:PERcent?
.........................................3
:COMParator:SLIMit:ABSolute?
.......................................2
:COMParator:SLIMit:DEViation?
.....................................3
:COMParator:SLIMit:PERcent?
.........................................3
:CORRection:LIMit:POINt
..................................................2
:CORRection:OPEN:DATA:ALL
.............................................. *
:CORRection:OPEN:DATA:SPOT
........................................... *
:CORRection:SHORt:DATA:ALL
........................................... *
:CORRection:SHORt:DATA:SPOT
......................................... *
:CORRection:LOAD:CONDition?
.........................................7
:CORRection:LOAD:DCResistance:CONDition?
...................2
:CORRection:LOAD:REFerence?
.........................................3
:CORRection:SCALe:DATA?
..................................................2
:DCResistance:RANGe:AUTO:LIMit
...................................2
:FILE:INFOrmation?
.............................................................5
:MEASure?
............................................................................... *
:MEASure:ITEM?
....................................................................3
:MONItor?
...............................................................................4
:RANGe:AUTO:LIMit
..............................................................2
:SAVE:MODE?
...........................................................................2
:SIGMa?
...................................................................................2
:SYSTem:DATE?
......................................................................3
:SYSTem:TIME?
......................................................................3
* The number of response messages varies depending on the
settings.
•
Queries producing responses as syntax checking is performed:
All queries produce responses when syntax checking is per-
formed.
•
Whether any queries produce responses when read:
There are no queries which produce response messages at the
instant they are read in by the controller.
•
Whether any commands are coupled:
There are no relevant commands.
Содержание IM3536
Страница 20: ...16 Operating Precautions ...
Страница 34: ...30 Screen Layout and Operation ...
Страница 140: ...136 Testing the System Self diagnosis ...
Страница 224: ...220 About Measurement Times and Measurement Speed ...
Страница 240: ...236 Discarding the Instrument ...
Страница 254: ...Appx 14 Dimensional Diagram Appx 10 Dimensional Diagram 230 114 15 48 33 33 25 35 119 1 330 1 Unit mm ...
Страница 264: ...Appx 24 Device Compliance Statement ...
Страница 270: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...