Chapter IV Function Parameter Table
94
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value
Change
terminal
function
selection
setting.
Note: The VDI virtual terminal is an
extension of the physical input
terminal. The communication sends
instructions to simulate the actual
terminal. Each bit in the
communication data represents a
terminal, and the value of each bit
represents the status of the
corresponding terminal. For specific bit
definition, please refer to the
communication address 0x1206
description.
The function of each terminal cannot
be the same. If the functions of the two
terminals are set to the same, the
physical terminal will act prior to the
virtual terminal in order, the DI ports
ranked first will work first, and the
latter ones will not work.
Fd.01
VDI2
terminal
function
selection
1
0
×
Fd.02
VDI3
terminal
function
selection
1
0
×
Fd.03
VDI4
terminal
function
selection
1
0
×
Fd.04
VDI5
terminal
function
selection
1
0
×
Fd.05
VDI6
terminal
function
selection
1
0
×
Fd.06
VDI7
terminal
function
selection
1
0
×
Fd.07
VDI8
terminal
function
selection
1
0
×
Fd.08
VDI9
terminal
function
selection
1
0
×
Fd.09
VDI10
terminal
function
selection
1
0
×
Fd.10
VDO1
terminal
function
selection
Same as F6.11
~
F6.13 function code
setting.
Note: The VDO virtual terminal is an
extension of the physical output
terminal. The virtual terminal status
can be read only through
communication. Each bit in the
communication data represents a
1
0
×
Fd.11
VDO2
terminal
function
selection
1
0
×