Chapter V Basic Operation Instructions
122
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
15: Set length arrival
16: Drive ready to run (RDY)
17: Drive fault
18: Reserved
19: Set cumulative running time arrival
20: Forward running
21: Reverse running
22: Reserved
23: Water supply sleep running indication
24: Water pipe overpressure indication
25: Water pipe under-pressure indication
26: Water pipe shortage indication
27: Water tank shortage indication
28:Water pipe break indication
Open
collector
output
terminal
DO (HDO
terminal)
F6.13
Relay
output
function
(TA/TB/T
C)
1
17
×
F6.26
DO output
switch
polarity 1
00000~11111
11111
11111
○
F6.29
DO1 output
on delay
Set range: 0.0
~
600.0s
This function code defines the delay from
the status change of the switch output
terminal and the relay to the output change.
0.1s
0.0s
○
F6.30
DO1 output
off delay
0.1s
0.0s
○
F6.31
DO2 output
on delay
0.1s
0.0s
○
F6.32
DO2 output
off delay
0.1s
0.0s
○
F6.33
Relay
output on
delay
0.1s
0.0s
○
F6.34
Relay
output off
delay
0.1s
0.0s
○
Fd.10
VDO1
terminal
function
selection
Same as F6.11
~
F6.13 function code
setting.
1
0
×
Fd.11
VDO2
terminal
function
selection
1
0
×
Fd.12
VDO3
terminal
function
1
0
×