Chapter V Basic Operation Instructions
112
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
time
F6.19
HDI
terminal
input mode
selection
(DI5)
0: Switch input
1: High-frequency pulse input (see
F5.19
~
F5.23)
1
0
×
5.5 Analog output
The HAV-SP series is configured with 2 analog output terminals (AO1 and AO2 are of
0~10V/0~20mA output, AO1 can select voltage input or current input through jumper J3, and AO2
can select voltage input or current input through jumper J4) and 1 high-speed pulse output terminal.
The proportional relationship can be adjusted by setting the maximum and minimum values
and their corresponding output percentages. The analog output signal can output the operation
frequency, output current, output torque, output voltage and output power in a certain proportion.
Related parameter table:
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
F5.24
HDO
function
selection
0: Running frequency (0
~
Maximum
output frequency)
1: Set frequency (0
~
Maximum output
frequency)
2: Output current (0
~
2 times rated
current)
3: Output torque (0
~
2 times rated
torque)
4: Output voltage (0
~
1.2 times rated
voltage)
5: Bus voltage (0
~
1000V)
1
5
○
F5.25
AO1
function
selection
1
0
○
F5.26
AO2
function
selection
1
1
○