Chapter V Basic Operation Instructions
124
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
selection
2: Keep the final value after a single
cycle
3: Continuous cycle
4: DI selective operation
LED tens digit: Start mode
0: Start running from the first stage
1: Continue running from the stage of
interruption
LED hundreds digit: Stage time unit
selection
0: Second
1: Minute
LED thousands digit: Store at power failure
0: Do not store at power failure
1: Stage at power failure storage
interruption
F9.01
Running
stages
1~16
1
16
○
F9.02
Multistage
instruction
1
Lower limit frequency ~ upper limit
frequency
0.01Hz 20.00H
z
○
F9.03
Stage 1
instruction
setting
LED single digit:
0: Multistage instruction 1 (F9.02)
1: AI1
2: AI2
3: Pulse frequency
4: Communication
5: Keypad digital potentiometer input
6: Reserved
LED tens digit:
0: Acceleration/deceleration time 1
1: Acceleration/deceleration time 2
2: Acceleration/deceleration time 3
3: Acceleration/deceleration time 4
LED hundreds digit:
0: Forward running
1: Reverse running
Note: Only the LED single digit
frequency source of stage 1 instruction
can be set.
111
005
○
F9.04
Stage 1
instruction
running
time
Set range: 0.1
~
6000.0
Note: For the time unit selection, see
F9.00 hundreds digit setting.
0.1
10.0
○
F9.05
Multistage
instruction
2
Stage X instruction (F9.05, F9.08, F9.11,
F9.14, F9.17, F9.20, F9.23, F9.26, F9.29,
F9.32, F9.35
、
F9.38, F9.41, F9.44, and
F9.47) setting range:
Lower limit frequency ~ upper limit
frequency
Stage X instruction (F9.06, F9.09, F9.12,
F9.15, F9.18, F9.21, F9.24, F9.27, F9.30,
F9.33, F9.36
、
F9.39, F9.42, F9.45, and
0.01Hz 20.00H
z
○
F9.06
Stage 2
instruction
setting
111
000
○
F9.07
Stage 2
instruction
running
time
0.1
10.0
○