Chapter V Basic Operation Instructions
131
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
F9.34
Stage 11
instruction
running time
0.1
10.0
○
F9.35
Multistage
instruction
12
0.01Hz
20.00Hz
○
F9.36
Stage 12
instruction
setting
111
000
○
F9.37
Stage 12
instruction
running time
0.1
10.0
○
F9.38
Multistage
instruction
13
0.01Hz
20.00Hz
○
F9.39
Stage 13
instruction
setting
111
000
○
F9.40
Stage 13
instruction
running time
0.1
10.0
○
F9.41
Multistage
instruction
14
0.01Hz
20.00Hz
○
F9.42
Stage 14
instruction
setting
111
000
○
F9.43
Stage 14
instruction
running time
0.1
10.0
○
F9.44
Multistage
instruction
15
0.01Hz
20.00Hz
○
F9.45
Stage 15
instruction
setting
111
000
○
F9.46
Stage 15
instruction
running time
0.1
10.0
○
F9.47
Multistage
instruction
16
0.01Hz
20.00Hz
○
F9.48
Stage 16
instruction
setting
111
000
○
F9.49
Stage 16
instruction
running time
0.1
10.0
○
5.10 PID control
The PID control is a commonly used method for process control. By performing proportional,
integral, and differential operations on the feedback signal of the controlled quantity and the
quantity of the target quantity signal, the output frequency of the drive is adjusted to form a