Chapter V Basic Operation Instructions
125
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value Change
F9.48) setting range:
LED single digit:
0: Multistage instruction x
1: Reserved
LED tens digit:
0: Acceleration/deceleration time 1
1: Acceleration/deceleration time 2
2: Acceleration/deceleration time 3
3: Acceleration/deceleration time 4
LED hundreds digit:
0: Forward running
1: Reverse running
Stage X instruction running time (F9.07,
F9.10, F9.13, F9.16, F9.19, F9.22, F9.25,
F9.28, F9.31, F9.34, F9.37
、
F9.40, F9.43,
F9.46, and F9.49) setting range:
0.1~6000.0
Note: For the time unit selection, see
F9.00 hundreds digit setting.
F9.08
Multistage
instruction
3
0.01Hz 20.00H
z
○
F9.09
Stage 3
instruction
setting
111
000
○
F9.10
Stage 3
instruction
running
time
0.1
10.0
○
F9.11
Multistage
instruction
4
0.01Hz 20.00H
z
○
F9.12
Stage 4
instruction
setting
111
000
○
F9.13
Stage 4
instruction
running
time
0.1
10.0
○
F9.14
Multistage
instruction
5
0.01Hz 20.00H
z
○
F9.15
Stage 5
instruction
setting
111
000
○
F9.16
Stage 5
instruction
running
time
0.1
10.0
○
F9.17
Multistage
instruction
6
0.01Hz 20.00H
z
○
F9.18
Stage 6
instruction
setting
111
000
○
F9.19
Stage 6
instruction
running
time
0.1
10.0
○
F9.20
Multistage
instruction
7
0.01Hz 20.00H
z
○
F9.21
Stage 7
instruction
setting
111
000
○
F9.22
Stage 7
instruction
running
time
0.1
10.0
○
F9.23
Multistage
instruction
8
0.01Hz 20.00H
z
○