Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 59 of 254
Command
Description
Parameters
<mode> MUX mode:
0 Basic
<subset>
Defines how the MUX control channel is set up. The virtual channel is
set up according to this setting.
0 UIH frames used only
<port_speed>
1 9600 bit/sec
2 19200 bit/sec
3 38400 bit/sec
4 57600 bit/sec
5 115200 bit/sec(default)
6 230400 bit/sec
7 1 M bit/s
<N1>
Maximum frame size: 1—1509;
The default value is 31 in Basic mode.
<T1>
Acknowledgement timer (in units of 10 ms).
1-255 The default value is 10 (100 ms)
<N2>
Maximum number of re-transmissions.
0-5 The default value is 3.
<T2>
Response timer for the DLC0 (in unit of 10 ms). <T2> must be longer than
<T1>.
2-255 The default value is 30 (300 ms).
<T3>
Wake up response timer (in seconds).
1-255 The default value is 10.
<k> Reserve for Advanced operation with Error Recovery options.
Example
T+CMUX=?
+CMUX: (0),(0),,(1-1509),(1-255),(0-5),(2-255),,
OK
AT+CMUX?
+CMUX: 0,0,,0,0,0,0,0,0
OK