![Fibocom L860-GL Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/fibocom/l860-gl/l860-gl_at-command-user-manual_2286851053.webp)
Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 53 of 254
Command
Description
<High> (-)–0 - 125; The Highest boundary level of the temperature value for
unsolicited report.
(Default value = 0 Celsius).
Setting corresponding <Low> and <High> temperature boundaries for <Report>=3
only.
Example
AT+MTSM=?
// Test the range of the parameters.
+MTSM: (0-3,6-7),(1-255),(-40-125)
OK
AT+MTSM=1
// Set to read for once the current temperature measurement.
+MTSM: 35
// Current temperature is +35 Celsius degree.
OK
AT+MTSM=2,5
// Set to unsolicited temperature reports to TE for every 5 seconds.
OK
+MTSM: -10
// Current temperature measure report -10 Celsius.
+MTSM: -5
// Unsolicited temperature report -5 Celsius after 5 seconds.
+MTSM: 7
// Unsolicited temperature measure 7 Celsius after 10 seconds.
+MTSM: 20 // Unsolicited temperature measure 20 Celsius after 15 seconds.
…
+MTSM: 50 // Unsolicited temperature measure 50 Celsius after Nx5 seconds.
AT+MTSM=0
// Set to stop the unsolicited report.
OK
AT+MTSM=3,30,-10,40
// Set to out-off boundary (-10 to +40 Celsius)
unsolicited reports for every 30 seconds.
OK
+MTSM: -20
// Unsolicited current report out-off the Low boundary.
+MTSM: -12
// Unsolicited report out-off the Low boundary after 30 seconds.
+MTSM: 47
// Unsolicited report out-off the High boundary after Nx30 seconds
AT+MTSM?
// Read the current setting.
+MTSM: 3,30,-10,40