unchanged. The MT responds with +CUSATW : <profile_storage>,<conflict_profile> where
<profile_storage> refers the conflicting profile followed by the final result code +CME ERROR: 3
(Operation not allowed). The rules for detecting conflicts are defined in 3GPP TS 31.111 [92].
Successful execution of the command does not result in any information response.
Command
Description
Set
[Function]
Set command without parameters resets stored TE and MT profiles to their default
values. Adding parameter <profile_storage> to the AT command resets only the
referred storage to its default value. Execution command issued with accompanied
parameter <profile>, stores the given <profile> to non-volatile memory in the MT.
[Syntax]
AT+CUSATW[=<profile_storage>[,<profile>]]
[Response/Action]
+CUSATW: <profile_storage>,<profile>[<CR><LF>+cusatw:
<profile_storage>,<profile>
[...]]
or
+CME ERROR: <err>
Read
N/A
Test
[Function]
Test command returns values supported as a compound value.
[Syntax]
AT+CUSATW=?
[Response/Action]
+CUSATW: (list of supported <profile_storage>s)
OK
Parameters
<profile_storage>
Is an integer type.
0 TE. Refers profile storage for the facilities supported by the TE. Default value is a
blank profile with all bits set to zero.
1 MT. Refers profile storage for the facilities to be
supported by MT, which can be a subset of the default MT facilities (see +CUSATW).