Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 52 of 254
Command
Description
Read
[Function]
Read the temperature.
[Syntax]
AT+MTSM?
[Response/Action]
+MTSM=<Report>[,<Rate>][,<Low>,<High>]
OK
Test
[Function]
[Syntax]
AT+MTSM=?
[Response/Action]
+MTSM: (range of <Report>),(range of <Rate>),(range of <Low>/<High>)
OK
Parameters
<Temp> -40 - 125; Temperature measurements in Celsius degrees.
<Report>
0: Deactivate unsolicited report.
1: Report once the current temperature.
2: Activate unsolicited report.
3: Activate unsolicited report only for out-off boundaries events.
6: Report the temperature of BBIC
7: Report the temperature of RF
<Rate> 1-255; Select the time interval in seconds between the unsolicited reports.
(Default value = 1 Second).
<Low> (-)–0 - 125; The lowest boundary level of the temperature value for
unsolicited report.
(Default value = 0 Celsius).
Setting corresponding <Low> and <High> temperature boundaries for <Report>=3
only.